Envoy provided support to the client following the initial opening up works and investigation phases on Station House.
Full review of 2no opening up inspections, fire consultant’s reports, site visit information, existing O&M manual, original building fire assessment and other information carried out to verify areas requiring remedial works and determine the optimum replacement strategy.
Early engagement with Envoy fire engineer and building control to verify initial proposals.
3no additional wall buildups containing a significant presence of combustible insulation identified that were not picked up by the 2 previous fire engineers.